Articles Related to Applications

P Yu, V Durgesh, H Johari - Bulletin of the American Physical Society, 2017

...Studies have shown that hemodynamics is integral to developing an understanding of aneurysm formation, growth, and rupture. This investigation focuses on a comprehensive study of the impact of varying inflow conditions and aneurysm shapes on spatial and temporal behavior of flow parameters and structures in an aneurysm.... ... For this purpose, detailed Particle Image Velocimetry (PIV) measurements were performed at the center plane of an idealized aneurysm model for a range of inflow conditions. Inflow conditions were precisely controlled using a ViVitro SuperPump system. ...

Other Products Cited:  Flow Visualization  SuperPump

Visit Source 
Chung-Dann Kan, MD, PhD, Jieh-Neng Wang, PhD, Wei-Ling Chen, PhD, Pong-Jeu Lu, PhD, Ming-Yao Chan, PhD, Chia-Hung Lin, PhD, Wan Chin Hsieh, MD The Journal of Thoracic and Cardiovascular Surgery, September 2017

...The current study investigated: (i) the function of the ePTFE trileaflet-valved conduits in an ex vivo experimental system and (ii) the short-term performance of the conduit in a porcine model to verify their clinical applicability.... ... valves. 168 Right ventricular function was simulated by using a digitally controlled hydraulic piston 169 SuperPump (ViViTro Labs, Victor, British Columbia, Canada), which generated a pulsating 170 flow to drive the chamber and send it into a compliant pulmonary artery. ...

Other Products Cited:  Heart Valve Testing  Pulse Duplicator

Visit Source 
A. Desai, T. Vafaee, P. Rooney, J.N. Kearney, H.E. Berry, E. Ingham, J. Fisher, L.M. Jennings Journal of the Mechanical Behavior of Biomedical Materials 14 September 2017

The use of decellularised biological heart valves in the replacement of damaged heart valves ... ...The purpose of this study was to assess the effect of low concentration sodium dodecyl sulphate decellularisation on the in vitro biomechanical and hydrodynamic properties of cryopreserved human aortic and pulmonary roots.... ... performance of the valve roots. A viscoelastic impedance adapter (VIA; Vivitro System Inc., Victoria BC, Canada) was used to deliver a more physiological ventricle pressure and flow waveform in the simulator. This system allowed for ...

Other Products Cited:  Pulsatile Flow Simulation  Pulse Duplicator

Visit Source 
Retta SM, Kepner J, Marquez S, Herman BA, S Shu MC, Grossman LW J Heart Valve Dis. 2017 Jan;26(1):72-80.

One of the first steps in qualifying a new prosthetic valve for eventual clinical use is preclinical flow performance testing in vitro... ...This collaborative effort between heart valve manufacturers and the Food and Drug Administration (FDA) was designed to evaluate the variability of the pulse duplicator test technology for pulsatile flow performance measurement in an interlaboratory round robin... ...A commercially available duplicator, the Vivitro system (Vivitro, Inc., Vancouver, Canada), was used at two centers. The design specifications are summarized in Table I....

Other Products Cited:  Heart Valve Testing  Pulse Duplicator

Visit Source 
Yen Ngoc NguyenMunirah IsmailFoad KabinejadianChi Wei OngEdgar Lik Wui TayHwa Liang Leo - Cardiovascular Engineering and Technology 2017

The increased understanding of right heart diseases has led to more aggressive interventions to manage functional tricuspid regurgitation (FTR)... ...In this study, a novel in vitro mock circulatory system that incorporated a realistic tricuspid valve apparatus in a patient-specific silicon right ventricle (RV) was designed and fabricated... ... A closed ventricular chamber housing the silicon RV model was connected to a closed atrial chamber at one end, and was directly connected to the pulsatile wave-generating piston pump (SuperPump AR series, ViVitro Labs Inc., Victoria, BC, Canada) at the other end to simu ...

Other Products Cited:  Heart Valve Testing  Pulse Duplicator

Visit Source 
Guangyu Zhu; Masakazu Nakao; Qi Yuan and Joon Hock Yeo Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 1: BIODEVICES, 186-189, 2017, Porto, Portugal

Truly stentless polymeric valve prosthesis can be a viable alternative for aortic valve replacement (AVR). In the present paper, the dynamic and hemodynamic performance of a novel designed expanded-polytetrafluoroethylene (ePTFE) stentless tri-leaflet valve was assessed experimentally.... ... The in-vitro tests were performed under time-varying physiological pressure by using the Vivitro pulse duplicator. ... The Vivitro pulse duplicator (Vivitro Systems Inc., Victoria, BC, Canada) was used to generate the physiological pressure and flow in the left ventricle and aorta. ...

Other Products Cited:  Pulsatile Flow Simulation  Pulse Duplicator

Visit Source 
M. Alizadeh, M. Cote, and A Branzan Albu P Sharma, FM Bianchi - Image Analysis 20th Scandinavian Conference, SCIA 2017,

...The valve orifi ce area over time, which informs on the opening and closing motion patterns, constitutes a key quality metric for PHV assessment... ...In this paper, we propose a novel orifi ce segmentation approach for automatic prosthetic heart valves quantitative performance analysis, based on the detection of the leaflet free edges to accurately extract the actual orifi ce area.

Other Products Cited:  Flow Visualization  Pulse Duplicator

Visit Source 
FM Cardoso, SS Furuie - Proc. of SPIE Vol, 2017

Ultrasound elastography has become an important procedure that provides information about the tissue dynamics and may help on the detection of tissue abnormalities. We propose a novel algorithm to perform speckle tracking, which consists in an implementation of 2D Block Matching with two enhancements: sub-pixel linear interpolation and displacement propagation, which are able to increase resolution, reduce computation time and prevent kernel mismatching errors. ... studies on their numerical analogs. Fig. 1 Section of the f20dX LV phantom. Dimensions in [mm]. METHODS Fig. 2 Experimental setup. 1 – GE Vivid 6 scanner; 2 – water tank; 3 – LV model; 4 – M4S-RS probe; 5 – windkessel; 6 – Vivitro Superpump; 7 – Pump Controller; 8 – PC. ...

Other Products Cited:  SuperPump  Ultrasound Measurements

Visit Source 
Lim, Brian. Muhammad Mujahid. Tan, Rong Wang. Arunkumar, U. Singapore Polytechnic School of Mechanical and Aeronautical Engineering

Coronary heart disease (CHD) is a common cardiac disorder in which a portion of the coronary artery is blocked, leading to a potential heart attack. Timely and accurate evaluation of suspected CHD patients is critical. Computer Tomography Angiography (CTA)... In order to streamline the evaluation of suspected CHD patients, we propose to create a more accurate and consistent diagnostic method of interpreting CTA results.

Other Products Cited:  Pulsatile Flow Simulation  SuperPump

Visit Source 
Ng, Daniel Wai Hung. Neo, Si Yang. Ng, Chung Liu. Wong, Benedict Jun Shuan. Singapore Polytechnic School of Mechanical & Aeronautical Engineering

...Mechanical valves usually made from metal and fabrics are very durable but they have poor hemodynamic and are thrombogenic requiring permanent anticoagulation. Tissue heart valves constructed from biological tissues have excellent hemodynamic blood flow, but they lack durability. The project proposed a new valve design that is similar to a stentless tissue valve but made from a synthetic material, Polytetrafluoroethylene (PTFE)... The scope of this project includes designing a fixture to accommodate the valves in the ViVitro System and studying hemodynamic parameters such as pressure drop, flow rate, and dynamic leaflet behaviour of the valves. ...

Other Products Cited:  Heart Valve Testing  Pulse Duplicator

Visit Source 
Andrew K. Capullia, Maximillian Y. Emmerta, b, c, Francesco S. Pasqualinia, b, Debora Kehlb, Etem Caliskanb, c, Johan U. Linda, Sean P. Sheehya, Sung Jin Parka, Seungkuk Ahna, Benedikt Webera, b, Josue A. Gossa, Simon P. Hoerstrupa, b, Kevin Kit Parkera; Biomaterials Volume 133, July 2017, Pages 229–241

Tissue engineered scaffolds have emerged as a promising solution for heart valve replacement because of their potential for regeneration. However, traditional heart valve tissue engineering has relied on resource-intensive, cell-based manufacturing, which increases cost and hinders clinical translation. ...We demonstrated controlled modulation of these scaffold parameters and show initial biocompatibility and functionality in vitro...

Other Products Cited:  Pulse Duplicator  Tissue Engineering

Visit Source 
Wentao Feng, Xianda Yang, Yang Liu, Yubo Fan Artificial Organs, 24 February 2017

Clinically, the percutaneous transcatheter aortic valve (TAV) has been reported to be deformed in a noncircular configuration after its implant. The deformation is universal and various, and it leads to serious leakage and durability problems. ...the present study investigated the effects of the aortic annulus deformation and the leaflet tissue thickness on the hydrodynamics of the TAV. ... Hydrodynamic testing. The TAVs were tested in a quasi-physiological artery pulsatile flow duplicator system, which was custom remoulded to adapt the testing of deformed TAV from commercially available pulse duplicator (Pulse Duplicator; Vivitro Labs, Victoria, BC, Canada.). ...

Other Products Cited:  Heart Valve Testing  Pulse Duplicator

Visit Source 
Ahmad Falahatpisheha, Daisuke Morisawaa, Taraz T. Tooskyb, Arash Kheradvara Journal of Biomechanics Available online 16 November 2016

...developed a novel polymeric valve whose leaflets possess calcium hydroxyapatite inclusions immersed in them. This study reports the characteristics and feasibility of these valves. ... The system is connected and actuated by a pulsatile pump system (Superpump system, VSI, SPS3891, Vivitro systems Inc., Victoria, BC, Canada), which operates based on a VSI Wave Generator VG2001 (Vivitro Systems Inc., Victoria, BC, Canada) and controlled by a ...

Other Products Cited:  Pulsatile Flow Simulation  SuperPump

Visit Source 
Keyvan Amini Khoiy, Dipankar Biswas, Thomas N Decker, Kourosh T Asgarian, Francis Loth and Rouzbeh Amini Circulation November 11, 2016, Volume 134, Issue Suppl 1

...study to establish a framework for the measurement of the deformation of TV leaflets in a passive ex-vivo beating heart that mimicked the right ventricular dynamic pressure of the normal hearts. ...apexes of fresh porcine hearts (n= 8) were connected to a positive displacement pump (SuperPump AR Series, Vivitro Labs Inc., BC) to generate pulsatile flow in the right side of the hearts. The superior vena cava was connected to a reservoir as the inflow pathway and the pulmonary artery was used for the outflow pathway...

Other Products Cited:  Ex ViVo Simulation  SuperPump

Visit Source 
Keyvan Amini Khoiy, Dipankar Biswas, Thomas N. Decker, Kourosh T. Asgarian, Francis Loth and Rouzbeh Amini; Journal of Biomechanical Engineering revised August 23, 2016

...For the first time, the porcine valve leaflets deformation was measured in a passive ex-vivo beating heart without isolating and remounting the valve annuli. In particular, the right ventricular apexes of porcine hearts (n = 8) were connected to a pulse-duplicator pump that maintained a pulsatile flow from and to a reservoir connected to the right atrium and the pulmonary arteries... A positive displacement pump 116 (SuperPump AR Series, Vivitro Labs Inc., BC, Canada) was connected to the apex of the right 117 ventricle after an incision was carefully made at this location (as described in more detail below)...

Other Products Cited:  Ex ViVo Simulation  SuperPump

Visit Source 
Onur Dur, Keif Fitzgerald, Paul Muller, Chris Parker Thoratec Corporation, Sunnyvale, CA company slide

The HeartMate PHP is a 13F catheter-based trans-aortic heart pump with a collapsible distal portion that expands to 24F to provide minimally invasive acute hemodynamic stabilization and left ventricular unloading in both prophylactic and emergent clinical settings... Objective: To evaluate the interaction of the HeartMate PHP with native cardiovascular system via in vitro pulsatile mock flow loop testing. A custom-built pulsatile heart simulator adapted from Vivitro Pulse Duplicator (Vivitro Labs Inc., Canada) was tuned to generate physiological flow pressure waveforms while mimicking the preload sensitivity of the native heart.

Other Products Cited:  Customized Circulatory Loop  Pulsatile Flow Simulation  Pulse Duplicator  VAD Testing

Visit Source 
Cole Feagler, Zeeshan Syedain and Robert Tranquillo University of Minnesota College of Science and Engineering Poster Report

While most commercial valves today use chemically-fixed porcine tissue in the construction of the replacement valves, the Tranquillo group has been exploring the use of decellularized, engineered tissue as leaflet material... ...The goal of this project was to engineer a commissure design to mitigate valve failure through tissue tearing, and to improve overall valve hemodynamics. (I.e. reduction of PVL)... ...Prototype TEHVs were tested to failure using a ViVitro Labs pulse duplicator, running custom LabView data acquisition software...

Other Products Cited:  Pulsatile Flow Simulation  Pulse Duplicator  Tissue Engineering

Visit Source 
Sean Guo-Dong Tan, Sangho Kim, Hwa Liang Leo Experiments in Fluids June 2016, 57:110

Mechanical heart valve prostheses are often implanted in young patients due to their durability and long-term reliability. However, existing designs are known to induce elevated levels of blood damage and blood platelet activation... ...This study proposes a bi-leaflet mechanical heart valve design (Bio-MHV) that mimics the geometry of a human mitral valve, with the aim of reducing turbulence levels in the left ventricle by replicating physiological flow patterns... ... A pulsatile pump (ViVitro Labs Inc., Victoria, BC) attached to the working chamber drove the blood analog around the flow loop, via the pumping action of the silicon left ventricle, as shown in Fig. 1c. Fig. 2 a A mitral flow waveform sample observed in the experiments. ...

Other Products Cited:  Pulsatile Flow Simulation  SuperPump

Visit Source 
Riccardo Toninatoa, Jacob Salmona, Francesca Maria Susin, Andrea Duccia, Gaetano Burriescia doi:10.1016/j.jbiomech.2016.05.027

The physiological flow dynamics within the Valsalva sinuses, in terms of global and local parameters, are still not fully understood. This study attempts to identify the physiological conditions as closely as possible, and to give an explanation of the different and sometime contradictory results in literature. ... 2. Material and Methods. In this study, all experiments were carried out using a hydro-mechanical pulse duplicator (Vivitro Superpump System SP3891, ViVitro Labs Inc., Canada), with pressure catheters monitoring the pressure upstream and downstream of the aortic valve. ...

Other Products Cited:  Flow Visualization  Pulse Duplicator

Visit Source 
Bernhard M. Vennemann , Thomas Rösgen, Thierry P. Carrel, Dominik Obrist - Article Cardiovascular Engineering and Technology pp 1-13 First online: 13 May 2016

The Lapeyre-Triflo FURTIVA valve aims at combining the favorable hemodynamics of bioprosthetic heart valves with the durability of mechanical heart valves (MHVs). ... physiological con- ditions. It is driven by a peristaltic pump (Superpump, Vivitro Systems, Victoria, BC, Canada) (1) which generates a directed pulsatile flow through the test section (3). The net flow through the transparent test section is ...

Other Products Cited:  Heart Valve Testing  SuperPump

Visit Source 

Join over 5000 cardiovascular device professionals who receive our testing and engineering insights and tips every month.