Articles Related to Ultrasound Measurements
Other Products
-
Accessories
-
Analysis and Computational Modeling
-
Applications
-
AWT with DCT
-
Customized Circulatory Loop
-
Customized circulatory systems
-
Endovascular Simulator
-
Ex ViVo Simulation
-
Flow Visualization
-
Heart Valve Repair
-
Heart Valve Testing
-
HiCycle Durability Tester
-
MRI compatibility
-
Peripheral devices testing
-
Pressure Measurement System
-
Products
-
Pulsatile Flow Simulation
-
Pulse Duplicator
-
Software
-
Stent and Stent/Graft
-
SuperPump
-
TAVI
-
Tissue Engineering
-
TMVR
-
VAD Testing
Hernandez Torres, S. I., Caldwell, N. W., & Snider, E. J. Bioengineering, 11(12), 1271.
Here, we conduct independent evaluation testing of the Vu-Path™ Ultrasound Guidance system, or Vu-Path™. The device was evaluated using a custom, modular tissue-mimicking phantom that can easily be adjusted to multiple different vessel diameters. The phantom was connected to a flow loop with a pulsatile, heart-mimicking pump (ViVitro Labs, Victoria, BC, Canada) circulating water, and pressure was quantified by sensors connected to a patient monitor. Overall, the Vu-Path™ device performed well for this vascular access task across the standardized test pipeline we presented.
Other Products Cited: Customized Circulatory Loop SuperPump
Visit SourceLeister, R., Karl, R., Stroh, L., Mereles, D., Eden, M., Neff, L., de Simone, R., Romano, G., Kriegseis, J., Karck, M., Lichtenstern, C., Frey, N., Frohnapfel, B., Stroh, A., & Engelhardt, S. Cardiovasc Eng Tech (2025).
In this study the accuracy of the flow convergence method was assessed in a hemodynamic reproducible in-vitro environment. The frequency of the pump (ViVitro SuperPump, ViVitro Labs, Inc., Victoria, Canada) is adjusted to 80 bpm and the stroke volume of the pump is set to reach a left ventricular pressure of approximately 120 mmHg. The most obvious finding is that the RVol determined by physicians with the flow convergence methods underestimates the RVol for eight out of nine MROPs.
Other Products Cited: Analysis and Computational Modeling Flow Visualization Heart Valve Testing Pulsatile Flow Simulation Pulse Duplicator
Visit SourceLevent Beker, Alp Toymus, Süleyman Peker, Abdülkadir Atik, Umut Yener, Maide Albay, Emel Yılgör, İskender Yılgör. Research Square. 08 January 2025.
Despite the rapid emergence of wearable ultrasound technologies in the research community, the common practice still requires wired connections to benchtop instruments. For the in vitro characterization of the heart rate and blood pressure monitoring US tag, a pulsatile pump (SuperPump, ViVitro Labs) with a silicone rubber vessel was used. Thanks to the advances in soft materials, fabrication techniques and sensing strategies, wearable medical devices are revolutionizing the healthcare system by enabling continuous and quantitative assessment of various biomarkers.
Other Products Cited: Customized Circulatory Loop Customized circulatory systems Pulsatile Flow Simulation SuperPump
Visit SourceMohl, L., Karl, R., Hagedorn, M.N. et al. Int J CARS (2024)
Complicated type B Aortic dissection is a severe aortic pathology that requires treatment through thoracic endovascular aortic repair (TEVAR). A realistic pulsatile flow through the aortic phantom is provided by a cardiac piston pump (Superpump, Vivitro Labs Inc., Victoria, Canada). The flexible aortic dissection phantom was successfully incorporated in the hemodynamic flow loop, a systolic pressure of 112 mmHg and physiological flow of 4.05 L per minute was reached.
Other Products Cited: Customized Circulatory Loop Flow Visualization Pulsatile Flow Simulation Stent and Stent/Graft SuperPump
Visit SourceDiya Wang, Boris Chayer, François Destrempes, Jonathan Porée, Marie-Hélène Roy Cardinal, François Tournoux, Guy Cloutier, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control (Volume: 69, Issue: 12, December 2022) Page(s): 3284 - 3296
Assessment of myocardial contractility during a stress test is of high clinical value for the diagnosis and evaluation of cardiovascular diseases, especially coronary disease and heart failure. Both ends of this left-ventricular mimicking phantom (wall thickness of 15 mm) was then connected to polyvinyl chloride tubing by a pair of loosely attached steel clamps to a pulse duplicator (model #SD2001-1, ViVitro systems Inc., Victoria, BC, Canada). The complex, large, and rapid myocardial deformation during stress tests were also accurately imaged by the proposed strain estimator with close agreement with sonomicrometry.
Other Products Cited: Endovascular Simulator Pulsatile Flow Simulation SuperPump
Visit SourceYuriy TASINKEVYCH, Marcin LEWANDOWSKI, Ziemowit KLIMONDA, Mateusz WALCZAK - Polish Academy of Sciences ARCHIVES OF ACOUSTICS Vol. 43, No. 3, pp. 437–446 (2018)
Commercially available cardiac scanners use 64–128 elements phased-array (PA) probes and classical delay-and-sum beamforming to reconstruct a sector B-mode image... ...The goal of this study was to show the feasibility of reducing the channel count in the diverging wave synthetic aperture image reconstruction method for phased-arrays.... … a water tank with dedicated absorbers at- tenuating the reflected waves (Aptflex F28 and Aptflex F28P, Precision Acoustics, UK), tubing system, wind- kessel (to reduce/eliminate phantom vibrations), Viv- itro Superpump …
Other Products Cited: SuperPump
Visit SourceJoão Gomes-Fonseca ; Pedro Morais ; Sandro Queirós ; Fernando Veloso ; António C. M. Pinho ; Jaime C. Fonseca ; Jorge Coreia-Pinto ; João L. Vilaça - 2018 IEEE 6th International Conference on Serious Games and Applications for Health (SeGAH)
This work aims to create a dynamic, ultrasound-compatible, realistic and flexible phantom of the left and right ventricles, with application in the diagnosis, planning, treatment and training in the cardiovascular field for studies using echocardiography. … the real tissues. Then, a commercial available computed-controlled dynamic piston pump (Vivitro Labs, Victoria, British Columbia, Canada) was used to pump water... into the model and consequently deform it. This pump system
Other Products Cited: SuperPump
Visit SourceFM Cardoso, SS Furuie - Proc. of SPIE Vol, 2017
Ultrasound elastography has become an important procedure that provides information about the tissue dynamics and may help on the detection of tissue abnormalities. We propose a novel algorithm to perform speckle tracking, which consists in an implementation of 2D Block Matching with two enhancements: sub-pixel linear interpolation and displacement propagation, which are able to increase resolution, reduce computation time and prevent kernel mismatching errors. ... studies on their numerical analogs. Fig. 1 Section of the f20dX LV phantom. Dimensions in [mm]. METHODS Fig. 2 Experimental setup. 1 – GE Vivid 6 scanner; 2 – water tank; 3 – LV model; 4 – M4S-RS probe; 5 – windkessel; 6 – Vivitro Superpump; 7 – Pump Controller; 8 – PC. ...
Other Products Cited: SuperPump
Visit SourceE Frankowska, Z Trawi; Poster No.: C-0473 Congress: ECR 2014 Type: Scientific Exhibit
... Model of the LV was made from solution of POLY(VINYL ALCOHOL). Pulsatile filling of the LV phantom was driven by automatic and computer controlled hydraulic piston pump (Vivitro Inc., Canada) with stroke volume of 20 ml and the frequency of 60 impactions per minute. ...
Other Products Cited: SuperPump
Visit SourceZ Trawiński, J Wójcik, A Nowicki, A Balcerzak…
... Our model of the LV was driven by the computer-controlled hydraulic piston Super-Pump (Vivitro Inc., Canada) with adjustable fluid volumes. ... The data were reconstructed every 10% of the R-to-R interval of the ECG signal produced by the Vivitro SuperPump control device. ...
Other Products Cited: Pulsatile Flow Simulation SuperPump
Visit SourcePoulsen, J.K. Kim, W.Y; IEEE Transactions on Biomedical Engineering: 43, Issue 6; 589-599.
In this paper we show that by scanning at points on the surface of a sphere that the normal angle correction used in pulsed Doppler flow measurements is no longer necessary.
Other Products Cited: SuperPump
Visit SourceJ.Mascherbauer, R.Rosenhek, B.Bittner, J.Binder, P.Simon, G.Maurer, H.Schima, H.Baumgartner; Journal of the American Society of Echocardiography: 18, Issue 10; 999-1006.
Other Products Cited: SuperPump
Visit SourceMano J. Thubrikar, PhDa, Francis Robicsek, MD, PhDa, Geoffrey G. Gong, MDa, Brett L. Fowler, BSa; The Annals of Thoracic Surgery: 71; S318-S322; 2001.
Other Products Cited: Heart Valve Testing Pulse Duplicator
Visit SourceToshihiro Ogawa, Lawrence N Scotten,** David K Walker**, Ajit P Yoganathan, Renee L Bess, Cheryl K Nordstrom, and Julius M Gardin; Cardiovasc Ultrasound; 2005. **ViVitro Labs Founder
Insufficient data describe the relationship of hemodynamic parameters to left ventricular (LV) diastolic flow propagation velocity (Vp) measured using color M-mode Doppler echocardiography.
Other Products Cited: Pulse Duplicator
Visit SourceJulia Mascherbauer, Christina Fuchs, Martin Stoiber, Heinrich Schima, Elisabeth Pernicka, Gerald Maurer and Helmut Baumgartner; European Heart Journal: 29, Issue 16; 2049-2057; 2008.
Hypertension is a frequent finding in patients with aortic stenosis (AS). However, controversial data about the influence of systemic blood pressure on the quantification of AS have been published.
Other Products Cited: SuperPump
Visit SourceJeffrey J. Heys, Nicole Holyoak, Anna M. Calleja, Marek Belohlavek and Hari P. Chaliki, The Open Biomedical Engineering Journal 4, 123-128; 2010.
The assessment of the severity of aortic valve stenosis is done by either invasive catheterization or non-invasive Doppler Echocardiography in conjunction with the simplified Bernoulli equation. The catheter measurement is generally considered more accurate, but the procedure is also more likely to have dangerous complications.
Other Products Cited: Pulse Duplicator
Visit SourceS Cygan, K Werys, Ł Błaszczyk, T Kubik, K Kałużyński – … and Biomedical Engineering, 2013
… 1 – Vivitro SuperPump, 2 – Vivitro controller, 3 – PC, 4 – constant pressure container, 5 – a phantom tank, 6 – the LV phantom, 7 – the body coil. … The phantom was deformed by a pump for hemodynamic simulations (SuperPump, Vivitro, Canada).
Other Products Cited: MRI compatibility
Visit Source