Ali N. Azadani, PhD, Nicolas Jaussaud, MD, Peter B. Matthews, BS, Liang Ge, PhD, T. Sloane Guy, MD, Timothy A.M. Chuter, MD, Elaine E. Tseng, MD.; Ann Thorac Surg 2009;88:1857-1863, Aug 11, 2009.
Other Products Cited: Heart Valve Testing
Visit SourceTravis BR, Fowler BL, Robicsek F.; J Heart Valve Dis. (5):499-506; Sep 18, 2009.
Other Products Cited: Heart Valve Testing Pulsatile Flow Simulation
Visit SourceThomas E. Claiborne, Danny Bluestein, Richard T. Schoephoerster, The International Journal of Artificial Organs, Vol. 32, no. 5, pp. 262-271; 2009.
Other Products Cited: Heart Valve Testing
Visit SourceJeffrey J. Heys, Nicole Holyoak, Anna M. Calleja, Marek Belohlavek and Hari P. Chaliki, The Open Biomedical Engineering Journal 4, 123-128; 2010.
The assessment of the severity of aortic valve stenosis is done by either invasive catheterization or non-invasive Doppler Echocardiography in conjunction with the simplified Bernoulli equation. The catheter measurement is generally considered more accurate, but the procedure is also more likely to have dangerous complications.
Other Products Cited: Ultrasound Measurements
Visit SourceMichel R. Labrosse, Keegan Lobo, Carsten J. Beller, Journal of Biomechanics 43, 1916–1922; 2010.
A novel finite element model of the natural aortic valve was developed implementing anisotropic hyperelastic material properties for the leaflets and aortic tissues, and starting from the unpressurized geometry. Static pressurization of the aortic root, silicone rubber moulds and published data helped to establish the model parameters, while high-speed video recording of the leaflet motion in a left-heart simulator allowed for comparisons with simulations.
Other Products Cited: Heart Valve Testing
Visit SourceAndrew D. Michaels MD, David Mester, Catheterization and Cardiovascular Interventions Vol. 77, issue 5, pages 726-732, April 2011.
Abstract OBJECTIVES: Accurate assessment of prosthetic mechanical valve malfunction is challenging for non-invasive and invasive techniques. We evaluated a 0.014-inch pressure-sensing coronary guidewire to assess mechanical valve dysfunction.
Other Products Cited: Heart Valve Testing
Visit SourceA Saini - 2011 - conservancy.umn.edu
The objective of this thesis is to 1) describe the product development cycle for the DS1000, a surgical instrument for Mitral Valve repair. A chapter is then provided for 2) adapting the device development cycle to a development cycle for a simulator. This is followed by 3)...
Other Products Cited: Ex ViVo Simulation
Visit SourceTE Claiborne III - dspace.sunyconnect.suny.edu
Valvular heart disease remains a significant public health issue with Calcific Aortic Valve Disease (CAVD) its most life threatening form. Current treatment for CAVD involves open-heart surgical replacement of the diseased aortic valve (AV) with either a tissue (THV) or mechanical (MHV) prosthesis, with THVs being mostly nonthrombogenic but vulnerable to structural valve deterioration (SVD) and MHVs being highly durable but thrombogenic, thus requiring lifelong anticoagulant therapy.
Other Products Cited: Heart Valve Testing
Visit SourceV Millette, N Baddour - Biomedical engineering online, 2011 - biomedcentral.com
Heart signals represent an important way to evaluate cardiovascular function and often what is desired is to quantify the level of some signal of interest against the louder backdrop of the beating of the heart itself. An example of this type of application is the quantification of cavitation in mechanical heart valve patients.
Other Products Cited: Heart Valve Testing
Visit SourceO Bazan, JP Ortiz - Revista Brasileira de Cirurgia Cardiovascular, 2011 - SciELO Brasil
Other Products Cited: Heart Valve Testing
Visit SourceAN Azadani, N Jaussaud, L Ge, … - The Annals of thoracic …, 2011 - Elsevier
Transcatheter aortic valve (TAV) implantation is a treatment for selected patients with failing bioprostheses. We previously showed that currently available SAPIEN (Edwards Lifesciences, Irvine, CA) TAV sizes did not yield acceptable valve-in-valve (VIV) hemodynamics in small degenerated bioprostheses because optimal TAV function requires full stent expansion to its nominal size.
Other Products Cited: Heart Valve Testing
Visit SourceF Robicsek, RF Padera Jr… - HSR proceedings in …, 2012 - ncbi.nlm.nih.gov
Other Products Cited: Heart Valve Testing
Visit SourceLN Scotten**, R Siegel - The Journal of heart valve disease, 2011 - icr-heart.com **ViVitro Labs Founder
The results of recent hematological studies have suggested that, under non-physiological flow conditions, circulating procoagulant proteins activate the coagulation cascade. In the present study, in-vitro estimates of flow transients at or near the time of valve closure, including regional backflow velocity (RBV, m/s), flow acceleration (m/s2), and rate of acceleration (jerk, m/s3), have shed new light on the blood-damage potential of prosthetic valves.
Other Products Cited: Heart Valve Testing
Visit SourceB Rahmani, S Tzamtzis, H Ghanbari, G Burriesci… - Journal of …, 2012 - Elsevier
Synthetic leaflet heart valves have been widely studied as possible alternatives to the current mechanical and bioprosthetic valves. Assessing the in vitro hydrodynamic function of these prostheses is of great importance to predict their hemodynamic behaviour prior to implantation. This study introduces an innovative concept of a low-profile semi-stented surgical aortic valve (SSAV) made of a novel nanocomposite polyurethane with a polycarbonate soft segment (PCU) and polyhedral oligomeric silsesquioxane (POSS) nanoparticles covalently bonded as a pendant cage to the hard segment.
Other Products Cited: Heart Valve Testing
Visit SourceS Ramaswamy, M Salinas, R Carrol… - Journal of visualized …, 2012 - europepmc.org
Limitations of currently available prosthetic valves, xenografts, and homografts have prompted a recent resurgence of developments in the area of tri-leaflet polymer valve prostheses. However, identification of a protocol for initial assessment of polymer valve hydrodynamic functionality is paramount during the early stages of the design process.
Other Products Cited: Heart Valve Testing
Visit SourceS Tzamtzis, J Yap, M Mullen, G Burriesci - 2011 - discovery.ucl.ac.uk
Other Products Cited: Heart Valve Testing
Visit SourceG Pisani, R Scaffa, O Ieropoli, EM Dell’Amico… – The Journal of Thoracic …, 2013 – Elsevier
The present in vitro study was designed to ascertain whether the presence of sinuses of Valsalva in the aortic root were able to regulate the valve effective orifice area and modulate the gradient across the valve independently from root compliance.
Other Products Cited: Heart Valve Testing
Visit SourceJournal of Biomechanical Engineering, doi:10.1115/1.4026576. H. Maleki, S. Shahriari, M. Labrosse, P. Pibarot and L. Kadem
Other Products Cited: Heart Valve Testing
Visit SourceMedical & Biological Engineering & Computing, January 2014, Volume 52, Issue 1, pp 1-8. H. Maleki, S. Shahriari, L. G. Durand, M. R. Labrosse, L. Kadem
Other Products Cited: Heart Valve Testing
Visit SourceJ Luo, SA Korossis, SPP Wilshaw, LM Jennings… – Tissue Engineering, 2014
… testing. The flow simulator has been described previously. 27 It mimicked the right heart and was controlled and monitored by the ViviTest software (Vivitro Systems Inc). The simulator was set up as described by Korossis et al. …
Other Products Cited: Software Tissue Engineering
Visit Source